Plumbing compliance testing, in one booking.
Backflow devices, fire service assemblies, and emergency showers and eyewash stations, tested where the dates allow in one visit. Results lodged where the rules require it, and one register sent back with every due date on it.
- NSW licence309265C, plumbing and gas
- ABN49 617 149 596
- InsuranceCertificates of currency before the first visit
- RemindersSent before each device is next due
- InductionsDone through your contractor system
- Workmanship12 months on installs
Every test your site owes, one booking.
PVS Plumbing’s compliance visit tests the plumbing devices most Western Sydney sites must keep certified, in one booking: testable backflow devices including fire service detector assemblies, and emergency showers and eyewash stations. Results are lodged where the rules require it, certificates are issued, and the site gets one register with every due date on it.
No asset list yet? The first visit makes one, and every visit after that runs from it.
The devices this visit covers.
Each has its own page with the detail. This visit brings them together on one day where the due dates allow it.
Backflow devices
Testable backflow devices, including RPZ and double check valves, tested annually and lodged with Sydney Water within 2 days.
Backflow testingFire service assemblies
Detector assemblies on fire service connections, tested annually alongside your other backflow devices.
Emergency showers and eyewash
Plumbed units flow tested and certified to AS 4775:2026, with the supply faults behind a failed test fixed.
Emergency shower & eyewashSomething else on the same site: a grease trap, a gas job, a maintenance account? See commercial plumbing for the full list, or send it all through the one enquiry below.
Why each test runs on its own clock.
The devices in this visit sit on different intervals and different rules. This is the calendar we work to.
| Device or system | How often | The rule | Who lodges or keeps the record |
|---|---|---|---|
| Testable backflow devices, such as RPZ and double check valves | When installed, then every 12 months | Sydney Water requires high and medium hazard devices to be tested by an accredited backflow plumber. A site that has not been assessed is treated as high hazard. | The tester lodges the results with Sydney Water within 2 days |
| Fire service connections | Every 12 months | Sydney Water requires a testable double check detector assembly on sprinkler and fire hydrant connections. As a medium hazard device it follows the same annual test rule as other backflow devices. | The tester, with Sydney Water |
| Emergency showers and eyewash stations | Regular activation, plus inspection and flow testing at the intervals in AS 4775:2026 | Workplaces that use hazardous chemicals must provide suitable emergency equipment (SafeWork NSW code of practice). AS 4775 was reissued in June 2026. | The site keeps the activation log; the plumber certifies the flow test |
| Gas installations | Every job | Certificate of Compliance through Building Commission NSW’s eCert portal, mandatory since 1 March 2026 | The gasfitter, within 5 business days |
| Grease traps and trade waste | Approval before discharge, then regular pump-outs | Sydney Water approval for trade wastewater; a grease trap needs a connection agreement | Pump-outs by an authorised liquid waste transporter, not the plumber |
The same plumber, every year.
PVS Plumbing has kept compliance dates for accounts including the Brickworks group, Penrith RSL and Knauf Gypsum for between 15 and more than 20 years. The same crew, the same register, no re-quoting argument on every visit.
What comes back with the visit.
- Licence 309265C. NSW plumbing and gas, current and on the public record.
- Certificates of currency. Public liability and workers compensation, sent before we attend.
- Test results lodged. Backflow results to Sydney Water within 2 days, where lodgement is required.
- One register. Every device, its last test date and its next due date, on one list.
- Reminders sent. Ahead of each due date, not a notice after it has passed.
- Inductions done once. Through your contractor management system, if the site runs one.
Based in Penrith, across Western Sydney.
What managers ask us.
Direct answers from a licensed NSW plumber. General information for sites in the Sydney Water area.
What is a plumbing compliance visit?
Can you test everything in one visit even if the due dates do not line up?
Do you lodge backflow results with Sydney Water for us?
We do not have a list of what devices are on site. Can you make one?
Can you work around our trading or production hours?
What happens if a device fails its test?
Do you cover grease traps or gas fitting in the same visit?
- Sydney Water · Backflow prevention for businesses: hazard ratings, annual testing and lodging results.
- Sydney Water · Backflow prevention for plumbers: who may test, and how results are lodged.
- SafeWork NSW · Managing risks of hazardous chemicals, code of practice: emergency equipment where chemicals are used.
Tell us what’s on site. We’ll map the dates.
List what you know, or paste the wording from a Sydney Water notice. Three short steps, and a reply within 48 hours.
Send us your asset list.
Three short steps. Fields marked ● are required. A plumber reads every enquiry and replies within 48 hours.